Aluminum Building Wire

Aluminum Building Wire

Aluminum Building Wire for building wire and fixed electrical installation routes.

Aluminum Building Wire is reviewed for building electrical systems where conductor material, insulation type, circuit route and local code requirement define selection.

  • Key Technical Points:
  • Building wire type and local code route should be confirmed before quotation.
  • Conductor material, temperature rating and wet/dry location rating affect final selection.
  • Application type should separate branch circuit, feeder and fixture wiring use.
  • UL, ASTM and project documentation should match the requested market route.
  • Product Overview

    Aluminum Building Wire should be selected according to the actual project route, not by product name alone. Before quotation, review wire type, conductor material, temperature rating, wet/dry location rating and local electrical code route. Datasheet wording, compliance documents and final supply notes should stay aligned with the selected standard and installation conditions.

    Applications

    • building branch circuits and feeders
    • commercial and residential electrical systems
    • conduit, raceway or building wiring installations
    • projects requiring conductor material and local code route confirmation

    Construction

    aluminum or 8000-series alloy conductor with insulation and jacket system according to building wire type. Final conductor size, temperature rating, wet/dry location rating and wire type, temperature rating and installation route should follow the selected code route.

    Marking on Cable

    FARWALK CABLE – Aluminum Building Wire – [standard] – [size] – [rating] – [year] – [meter mark]

    Cable Identification

    • Insulation color, conductor identification and printed marking can be matched to the requested building wire type.
    • Wire type, conductor size and temperature rating should remain clear in product marking when required.

    Standards

    • UL 83
    • UL 44
    • UL 854
    • ASTM B800 / B801 where applicable

    Main Features

    Aluminum Building Conductor

    Aluminum or 8000-series alloy wire supports cost and weight control in building feeder applications.

    Size Conversion Review

    Ampacity and voltage drop should be compared against copper conductors according to local code.

    Service and Feeder Fit

    For Aluminum Building Wire, commonly reviewed for service entrance, feeder and panel routes where aluminum conductors are accepted.

    Product Selection Guide

    Wire Type

    Confirm THHN/THWN-2, XHHW-2, THW, TFFN/TFN, SER or SEU before selecting conductor and insulation.

    Local Code Route

    Building wire must follow the destination market electrical code and approved installation method.

    Wet / Dry Location

    Review insulation rating, jacket type and temperature class according to conduit, raceway or service entrance use.

    Conductor Material

    Choose copper, aluminum or 8000-series alloy according to ampacity, voltage drop, termination and budget.

    Technical Data Overview

    Size (AWG / kcmil) Approx. mm² Equivalent Approx. OD (XHHW-2 mils/mm) Approx. Weight (lb/kft) Allowable Ampacity @ 90°C (Amps)
    AA-8000 Aluminum Building Wire – 600V AA-8000 Aluminum Building Wire – 600V AA-8000 Aluminum Building Wire – 600V AA-8000 Aluminum Building Wire – 600V AA-8000 Aluminum Building Wire – 600V
    8 AWG 8.37 233 / 5.9 35 45
    6 AWG 13.30 271 / 6.9 51 60
    4 AWG 21.15 317 / 8.1 76 75
    2 AWG 33.62 379 / 9.6 116 100
    1/0 AWG 53.49 475 / 12.1 185 135
    2/0 AWG 67.43 520 / 13.2 228 150
    4/0 AWG 107.22 632 / 16.1 349 205
    250 kcmil 126.68 705 / 17.9 420 230
    500 kcmil 253.35 910 / 23.1 805 350