Covered Conductor

Covered Conductor

Covered Conductor for protected overhead distribution and tree-contact risk reduction.

Covered Conductor is used on overhead routes where an insulated or covered conductor surface is required to reduce contact risk and improve distribution line reliability.

  • Key Technical Points:
  • Designed for overhead distribution or service connection routes rather than indoor cable routes.
  • Conductor size, core arrangement and messenger requirement should be confirmed from the project drawing or utility standard.
  • Insulation and weather resistance should match outdoor exposure, voltage grade and installation method.
  • Datasheet, standard route and quotation can be prepared after voltage, size, quantity and destination are confirmed.
  • Product Overview

    Covered Conductor should be selected according to the actual project route, not by product name alone. Before quotation, review voltage grade, core arrangement, messenger or neutral design, insulation system and utility standard. Datasheet wording, compliance documents and final supply notes should stay aligned with the selected standard and installation conditions.

    Applications

    • covered overhead distribution lines
    • tree-contact or vegetation-sensitive routes
    • urban and rural medium-voltage distribution upgrades
    • overhead lines requiring additional insulation coverage

    Construction

    Aluminum or alloy conductor with weather-resistant insulation or covering. Thickness, voltage class, conductor size and covering material should be reviewed according to the selected overhead distribution standard.

    Marking on Cable

    FARWALK CABLE – Covered Conductor – [standard] – [voltage] – [size] – [year] – [meter mark]

    Cable Identification

    • Core color or numbering can be reviewed according to utility practice.
    • Outer insulation color and printing should follow the inquiry or project standard.

    Standards

    • IEC 60502-1 / IEC 60502-2
    • BS 7870
    • AS/NZS 3560.1 / AS/NZS 3599.1
    • project utility requirements

    Main Features

    Covered Overhead Protection

    Covered or aerial insulated construction reduces contact risk compared with bare overhead conductor routes.

    Tree and Urban Route Use

    Suitable for distribution routes where vegetation, space limitation or contact protection must be considered.

    Voltage and Covering Review

    For Covered Conductor, conductor material, insulation thickness and covering type should match voltage class and local utility practice.

    Product Selection Guide

    Voltage and Route

    Separate LV ABC, MV ABC, service drop, covered conductor and tree wire before selecting construction.

    Phase Arrangement

    Confirm duplex, triplex, quadruplex, single-core or bundled configuration according to the service route.

    Messenger / Neutral

    Review messenger material, neutral conductor, full neutral or self-supporting design with the utility requirement.

    Weather and Fittings

    Check UV exposure, temperature, fittings, span length and local utility standard before final selection.

    Technical Data Overview

    Cond. Size Strands Dia. over
    Cond. (in.)
    Inner
    (mil)
    Outer
    (mil)
    Approx. OD
    (in.)
    Weight
    (lb/kft)
    Rated Strength
    (lb)
    4 AWG 6/1 0.250 75 75 0.580 149 1767
    2 AWG 6/1 0.316 75 75 0.646 200 2708
    1/0 AWG 6/1 0.398 75 75 0.728 278 4161
    2/0 AWG 6/1 0.447 75 75 0.777 330 5045
    3/0 AWG 6/1 0.502 75 75 0.832 393 6289
    4/0 AWG 6/1 0.563 75 75 0.893 471 7933
    266.8 kcmil 18/1 0.609 75 75 0.939 474 6536
    266.8 kcmil 26/7 0.642 75 75 0.972 553 10735
    336.4 kcmil 18/1 0.684 75 75 1.014 570 8246
    336.4 kcmil 26/7 0.720 75 75 1.050 669 13395
    336.4 kcmil 30/7 0.741 75 75 1.071 935 16435
    397.5 kcmil 18/1 0.743 75 75 1.073 653 9443

    Global Engineering & Project Support

    Our technical team is ready to discuss customized cable solutions, compliance documentation, and optimized supply chain strategies for your international projects.

    REQUEST A QUOTE