Copper-Clad Steel Construction
Combines steel mechanical strength with a copper surface for selected grounding, signal or support applications.
Copper-clad steel strand for applications requiring mechanical strength and copper surface conductivity.
CCS combines the strength of steel with a copper-clad surface, supporting grounding, bonding, messenger and selected utility applications where both strength and conductivity are reviewed.
CCS is a copper-clad steel strand product designed for projects that require the mechanical strength of steel and the electrical surface characteristics of copper. It should be specified by application duty, conductivity requirement and mechanical strength rather than by name only.
Steel wire or strand with copper cladding. Final copper cladding type, conductivity requirement, wire diameter, stranding and breaking strength should be reviewed according to the project specification.
Combines steel mechanical strength with a copper surface for selected grounding, signal or support applications.
Used when the project needs better mechanical strength than pure copper with a controlled conductive layer.
For CCS - Copper Clad Steel Strand, copper thickness, conductivity class, wire diameter and stranding should be confirmed before quotation.
| Product / Route | Main Use | Selection Guidance |
| CCS | Copper surface plus steel strength | Grounding, bonding and selected utility support applications. |
| ACS | Aluminum-clad steel surface | Overhead line support or shield applications with aluminum-clad surface requirement. |
| GSW | Galvanized steel strand | General guying and mechanical support without copper surface requirement. |
Confirm whether the project uses IEC, ASTM, BS, DIN, GB, AS or NFC conductor tables before selecting size.
Compare nominal area, DC resistance and current requirement against the line design and utility specification.
Check rated strength, span length, sag requirement and wind/ice conditions before confirming conductor family.
For higher tension or corrosion performance, compare AAC, AAAC, ACSR, ACAR, AACSR or ACSR/AW as applicable.
| Size Designation | Area (mm²) | No. of Wires | Conductor Dia. (mm) | Weight (kg/km) | Max. DC Resistance at 20°C (Ω/km) |
| 19 No. 5 | 318.71 | 19 | 23.11 | 2660.8 | 0.1442 |
| 19 No. 6 | 252.71 | 19 | 20.57 | 2110.2 | 0.1818 |
| 19 No. 7 | 200.45 | 19 | 18.31 | 1674.2 | 0.2294 |
| 19 No. 8 | 158.97 | 19 | 16.31 | 1327.4 | 0.2890 |
| 19 No. 9 | 126.06 | 19 | 14.53 | 1052.6 | 0.3645 |
Our technical team is ready to discuss customized cable solutions, compliance documentation, and optimized supply chain strategies for your international projects.
REQUEST A QUOTE