Medium Voltage ABC Cable

Medium Voltage ABC Cable

Medium Voltage ABC Cable for medium-voltage aerial bundled cable distribution routes.

Medium Voltage ABC Cable is reviewed for overhead bundled distribution routes where conductor size, insulation system, messenger support and utility standard need to match the project voltage class.

  • Key Technical Points:
  • Designed for overhead distribution or service connection routes rather than indoor cable routes.
  • Conductor size, core arrangement and messenger requirement should be confirmed from the project drawing or utility standard.
  • Insulation and weather resistance should match outdoor exposure, voltage grade and installation method.
  • Datasheet, standard route and quotation can be prepared after voltage, size, quantity and destination are confirmed.
  • Product Overview

    Medium Voltage ABC Cable should be selected according to the actual project route, not by product name alone. Before quotation, review voltage grade, core arrangement, messenger or neutral design, insulation system and utility standard. Datasheet wording, compliance documents and final supply notes should stay aligned with the selected standard and installation conditions.

    Applications

    • overhead distribution network construction
    • rural electrification and utility feeder upgrades
    • pole-mounted secondary or medium-voltage routes
    • projects requiring bundled insulated overhead cable supply

    Construction

    Aerial bundled cable construction with insulated phase conductors and messenger or neutral arrangement according to voltage grade. Final conductor material, insulation, core count and support design should follow the required standard.

    Marking on Cable

    FARWALK CABLE – Medium Voltage ABC Cable – [standard] – [voltage] – [size] – [year] – [meter mark]

    Cable Identification

    • Core color or numbering can be reviewed according to utility practice.
    • Outer insulation color and printing should follow the inquiry or project standard.

    Standards

    • IEC 60502-2
    • project utility requirements

    Main Features

    Medium-Voltage Bundled Route

    MV ABC construction should be reviewed by voltage grade, insulation level, messenger system and utility standard.

    Compact Overhead Distribution

    Bundled insulated conductors support overhead distribution routes where space and safety clearance are important.

    Test and Accessory Coordination

    For Medium Voltage ABC Cable, cable, fittings, terminations and voltage tests should be checked together for the project route.

    Product Selection Guide

    Voltage and Route

    Separate LV ABC, MV ABC, service drop, covered conductor and tree wire before selecting construction.

    Phase Arrangement

    Confirm duplex, triplex, quadruplex, single-core or bundled configuration according to the service route.

    Messenger / Neutral

    Review messenger material, neutral conductor, full neutral or self-supporting design with the utility requirement.

    Weather and Fittings

    Check UV exposure, temperature, fittings, span length and local utility standard before final selection.

    Technical Data Overview

    Configuration Cond. Dia.
    (mm)
    Insulation
    (mm)
    Insul. Screen
    (mm)
    Sheath
    (mm)
    Support
    (No/mm)
    Overall Dia.
    (mm)
    Weight
    (kg/km)
    Still Air
    (A)
    1 m/s
    (A)
    2 m/s
    (A)
    3×35 6.9 3.4 0.8 1.2 7/4.75 52.4 1370 110 155 185
    3×50 8.1 3.4 0.8 1.2 7/4.75 54.6 1530 130 185 225
    3×70 9.7 3.4 0.8 1.2 7/4.75 57.8 1790 160 235 280
    3×95 11.4 3.4 0.8 1.2 7/4.75 61.3 2100 195 285 345
    3×120 12.8 3.4 0.8 1.2 19/3.50 67.3 2540 230 335 405
    3×150 14.2 3.4 0.8 1.2 19/3.50 70.1 2840 255 380 460
    3×185 15.7 3.4 0.8 1.2 19/3.50 73.1 3190 295 440 530

    Global Engineering & Project Support

    Our technical team is ready to discuss customized cable solutions, compliance documentation, and optimized supply chain strategies for your international projects.

    REQUEST A QUOTE