Shielded Mining Cable
SHD-style construction is reviewed where shielding, grounding and medium-voltage mine power safety are required.
SHD-PCG Mining Cable for mining, portable power and heavy-duty industrial routes.
SHD-PCG Mining Cable is used for mining and heavy-duty power routes where abrasion, flexibility, grounding, shielding and voltage class affect cable selection.
SHD-PCG Mining Cable should be selected according to the actual project route, not by product name alone. Before quotation, review equipment duty, voltage class, grounding or ground-check requirement, shielding, flexibility and abrasion exposure. Datasheet wording, compliance documents and final supply notes should stay aligned with the selected standard and installation conditions.
Flexible copper conductor construction with rubber insulation, ground conductor or ground-check conductor where required, shielding for SHD routes and heavy-duty rubber sheath. Voltage class, conductor size, shield/ground design and mine standard should be confirmed before supply.
FARWALK CABLE – SHD-PCG Mining Cable – [standard] – [voltage] – [core x size] – [year] – [meter mark]
SHD-style construction is reviewed where shielding, grounding and medium-voltage mine power safety are required.
GC, PCG or CGC versions should be selected according to monitoring and grounding design.
For SHD-PCG Mining Cable, voltage class, conductor size, shield system and jacket toughness should match the mine operating environment.
Separate Type W, G-GC, MP-GC, SHD, SHD-GC, SHD-PCG and SHD-CGC before selecting construction.
Confirm 2kV, 5kV, 8kV, 15kV, 25kV or higher project voltage before reviewing insulation and shield design.
Select grounding, ground-check, pilot or shielded construction according to mine safety requirements.
Mechanical Duty Check dragging, abrasion, bending radius, reeling, temperature and chemical exposure before selecting jacket material.
| Size (AWG / kcmil) | Approx. OD (mm) | Approx. Weight (kg/km) | Current Rating @ 90°C (Amps) | Control Core Size (AWG) | Min. Bending Radius (mm) |
| 3-Core SHD-PCG – 8000 Volts (Power + Control + Ground Check) | 3-Core SHD-PCG – 8000 Volts (Power + Control + Ground Check) | 3-Core SHD-PCG – 8000 Volts (Power + Control + Ground Check) | 3-Core SHD-PCG – 8000 Volts (Power + Control + Ground Check) | 3-Core SHD-PCG – 8000 Volts (Power + Control + Ground Check) | 3-Core SHD-PCG – 8000 Volts (Power + Control + Ground Check) |
| 2 AWG | 46.2 | 3850 | 130 | 14 (x2) | 375 |
| 1/0 AWG | 56.5 | 5450 | 175 | 12 (x2) | 455 |
| 2/0 AWG | 60.8 | 6250 | 200 | 12 (x2) | 490 |
| 4/0 AWG | 68.2 | 8150 | 260 | 10 (x2) | 550 |
| 350 kcmil | 79.5 | 11850 | 365 | 8 (x2) | 640 |
| 500 kcmil | 89.2 | 15450 | 445 | 6 (x2) | 720 |
Our technical team is ready to discuss customized cable solutions, compliance documentation, and optimized supply chain strategies for your international projects.
REQUEST A QUOTE