Flame-Retardant Control Route
Flame-retardant sheath or insulation materials support control circuits with fire-performance requirements.
Flame Retardant Control Cable for control, signal and instrumentation circuits.
Flame Retardant Control Cable is reviewed for control circuits where flame performance, smoke emission or building safety requirements must be considered.
Flame Retardant Control Cable should be selected according to the actual project route, not by product name alone. Before quotation, review core count, conductor size, insulation material, screen or armour requirement and control-system route. Datasheet wording, compliance documents and final supply notes should stay aligned with the selected standard and installation conditions.
Annealed copper conductor with PVC or XLPE insulation, optional overall screen, pair screen, armour and sheath according to route requirements. Core numbering, pair identification and flame/LSZH properties should follow the selected standard.
FARWALK CABLE – Flame Retardant Control Cable – [standard] – [voltage] – [core/pair x size] – [year] – [meter mark]
Flame-retardant sheath or insulation materials support control circuits with fire-performance requirements.
Suitable for control wiring in plants, substations and equipment systems where flame spread must be reviewed.
For Flame Retardant Control Cable, construction and documents should align with the specified flame-retardant test route.
Confirm whether the cable is for control, auxiliary, instrumentation, signal or panel wiring before selecting structure.
Define core count, pair or triad arrangement, conductor size and identification method from the wiring diagram.
Use screened or armoured versions when electromagnetic interference or mechanical protection is required.
Select PVC, XLPE, LSZH or flame-retardant construction according to environment and fire-safety requirements.
| No. of Cores x Cross Section (mm²) | Nominal Conductor Dia. (mm) | Nominal Insulation Thick. (mm) | Nominal Sheath Thick. (mm) | Approx. Overall Dia. (mm) | Max. DC Resistance @ 20°C (Ω/km) |
| 450/750V ZR-KVV Control Cable (Stranded Copper – Class B Rating) | 450/750V ZR-KVV Control Cable (Stranded Copper – Class B Rating) | 450/750V ZR-KVV Control Cable (Stranded Copper – Class B Rating) | 450/750V ZR-KVV Control Cable (Stranded Copper – Class B Rating) | 450/750V ZR-KVV Control Cable (Stranded Copper – Class B Rating) | 450/750V ZR-KVV Control Cable (Stranded Copper – Class B Rating) |
| 2 x 1.5 | 1.56 | 0.7 | 1.2 | 8.5 | 12.1 |
| 3 x 1.5 | 1.56 | 0.7 | 1.2 | 9.0 | 12.1 |
| 4 x 1.5 | 1.56 | 0.7 | 1.2 | 9.8 | 12.1 |
| 5 x 1.5 | 1.56 | 0.7 | 1.2 | 10.6 | 12.1 |
| 7 x 1.5 | 1.56 | 0.7 | 1.2 | 11.5 | 12.1 |
| 2 x 2.5 | 2.01 | 0.8 | 1.2 | 10.0 | 7.41 |
| 3 x 2.5 | 2.01 | 0.8 | 1.2 | 10.5 | 7.41 |
| 4 x 2.5 | 2.01 | 0.8 | 1.2 | 11.5 | 7.41 |
| 5 x 2.5 | 2.01 | 0.8 | 1.2 | 12.5 | 7.41 |
| 7 x 2.5 | 2.01 | 0.8 | 1.2 | 13.6 | 7.41 |
Our technical team is ready to discuss customized cable solutions, compliance documentation, and optimized supply chain strategies for your international projects.
REQUEST A QUOTE